dear experts:
参数: 运行环境matlab2013a,spm8update ,试过spm12update, spm8 ,spm12; 也试过matlab2010a,都不能run。
Q1:如果把slice timing 这一步不勾选,则能够运行到normalize to MNI space,why?
Q2:运行到normalize to MNI space后没有报错,也不继续,怎么没有接着smooth,why?
谢谢~
time points:240 TR:2.2 SLICE number:36 slice order:[1:2:35,2:2:36] (不太确定) reference frame 不知道没填 voxel size:3.4x3.4x3 其他默认值,报错内容如下。
Chris Rorden's dcm2nii :: 1 April 2010
reading preferences file D:\ProgramFiles\DPARSF_V2.3_130615\dcm2nii\dcm2nii.ini
reading preferences file DCM2NII.INI
Validating 240 potential DICOM images.
Found 240 DICOM images.
Converting 240/240 240
461->20150922_094526ep2dpacemoco240v201509101s003a001A.nii
Saving D:\PROGRAMFILES\ANALYSIS\FUNIMG\SUB02\20150922_094526ep2dpacemoco240v201509101s003a001A.nii
Time elapsed 1544ms
Converting Functional Images:sub02 OK
Warning: Directory already exists.
> In DPARSFA_run>(parfor body) at 225
In parallel_function at 473
In DPARSFA_run at 223
In DPARSFA>pushbuttonRun_Callback at 1601
In gui_mainfcn at 96
In DPARSFA at 33
Chris Rorden's dcm2nii :: 1 April 2010
reading preferences file D:\ProgramFiles\DPARSF_V2.3_130615\dcm2nii\dcm2nii.ini
reading preferences file DCM2NII.INI
Validating 176 potential DICOM images.
Found 176 DICOM images.
Converting 176/176 1
202->20150922_094526MPRAGE201509101s004a1001C.nii
Saving D:\PROGRAMFILES\ANALYSIS\T1IMG\SUB02\20150922_094526MPRAGE201509101s004a1001C.nii
Reorienting as D:\PROGRAMFILES\ANALYSIS\T1IMG\SUB02\o20150922_094526MPRAGE201509101s004a1001C.nii
Saving D:\PROGRAMFILES\ANALYSIS\T1IMG\SUB02\o20150922_094526MPRAGE201509101s004a1001C.nii
Cropping NIfTI/Analyze image D:\PROGRAMFILES\ANALYSIS\T1IMG\SUB02\o20150922_094526MPRAGE201509101s004a1001C.nii
Saving D:\PROGRAMFILES\ANALYSIS\T1IMG\SUB02\co20150922_094526MPRAGE201509101s004a1001C.nii
Time elapsed 920ms
Converting T1 Images:sub02 OK
??? Index exceeds matrix dimensions.
Error in ==> DPARSFA_run>(parfor body) at 553
delete(DirImg(j).name);
Error in ==> parallel_function at 491
S = F(base, limit);
Error in ==> DPARSFA_run at 528
parfor i=1:AutoDataProcessParameter.SubjectNum
Error in ==> DPARSFA>pushbuttonRun_Callback at 1601
[Error]=DPARSFA_run(handles.Cfg);
Error in ==> gui_mainfcn at 96
feval(varargin{:});
Error in ==> DPARSFA at 33
gui_mainfcn(gui_State, varargin{:});
??? Error while evaluating uicontrol Callback
Forums
Hi,
Hi,
From the error message:
Seems there were some problems with the NifTI files. Could you check if there are any .hdr/.img files under FunImg?
Best,
Chao-Gan
there is one img file under FunImg,i also try dpabi, error again
there is one img file under FunImg, it is a multi-volume file. it contains 240 imgs
problem has been solved
I use the basic version, slice timing can do.
but i counter another problem. one subject image is so strange, which don't like to be cut by the machine. frontal gyrus has a black area, what is wrong with this subject? if I reorient image incorrectly?
Hi Yin,
Hi Yin,
This is pretty common on EPI BOLD images. This is dropout because of air, bone, tissue, etc.
Best,
Chao-Gan